Handbook for Heat Exchangers and Tube Banks design (Paperback, 2010 ed.)


The recently published book by the author, "Engineering Heat Transfer", already dealt with exact computation of heat exchangers and tube banks. In design c- putationthisisaccomplishedviacorrectivefactors;thelattermakesitpossibleto compute the actual mean temperature difference by starting from the logarithmic onerelativeto?uidsinparallel?oworcounter?ow. As far as veri?cation computation is concerned, corrective factors were int- ducedtocomputeacertaincharacteristicfactorcorrectly,asisfundamentalforthis typeofcomputation. Basedontheabove,theauthordecidedtoinvestigatefurther,re?ne,andwiden thistopic:theoutcomeofthisworkhasresultedinthishandbook. Newtypesofexchangerswereexamined;thecalculationwasre?nedtoproduce practicallyexactvaluesforthefactors. Thescopeoftheinvestigationwasincreased by widening the range of the starting factors. Furthermore, a greater number of valuestobeincludedinthetableswasconsidered. Finally,afewcharacteristicsof certainvaluesofthecorrectivefactorswerehighlighted. The?rstsectionisanintroduction;itsummarizesthefundamentalcriteriaofheat transferandproceedstoillustratethebehaviorof?uidsinbothparallelandcounter ?ow. Italsoshowshowtocomputethemeanisobaricspeci?cheatforsome? uids; itillustratesthesigni?canceofdesigncomputationandveri?cationcomputation. In addition,itillustrateshowtoproceedwithheatexchangersandtubebankstocarry outbothdesignandveri?cationcomputationcorrectly. AppendixAthenincludes36tablesasareferencefordesigncomputation,The tablescontainthecorrectivefactorsrequiredtoobtaintheactualmeantemperature differencebystartingfromthemeanlogarithmictemperaturedifferencerelativeto ?uidsinparallel?oworcounter?ow. Finally, Appendix B includes 35 tables for veri?cation computation. As far as heatexchangers areconcerned, itshowsthevaluesoffactor ? whichisrequired forthistypeofcomputation. Thevaluesofthecorrectivefactorsforcoilsandtube banksarealsopresented. Milano,Italy DonatelloAnnaratone v Notation c=speci?cheat(J/kgK) d=diameter(m) E=ef?ciencyfactor h=enthalpy(kJ/kg) k=thermalconductivity(W/mK) M=mass?owrate(kg/s) m=massmoisturepercentage(%) q=heatpertimeunit(W) 2 S=surface(m ) ? t=temperature( C) 2 U=overallheattransfercoef?cient(W/m K) x=thickness(m) 2 ? =heattransfercoef?cient(W/m K) ? =characteristicfactor ? =characteristicfactor ? =ef?ciency ? =correctivefactor ? =correctivefactor ? =characteristicfactor ? ?t =temperaturedifference( C) vii viii Notation Superscripts =heating?uid =heated?uid Subscripts c=counter?ow e=exchanger i=inside l=logarithmic m=mean o=outside p=constantpressure(isobaric),parallel?ow w=wall 1=inlet(forheatingorheated?uid) 2=outlet(forheatingorheated?uid) Contents 1 Introduction to Computation ...1 1. 1 GeneralConsiderations ...1 1. 2 MeanIsobaricSpeci?cHeat ...3 1. 2. 1 WaterandSuperheatedSteam ...4 1. 2. 2 AirandOtherGases...4 2 Design Computation...7 2. 1 Introduction ...7 2. 2 FluidsinParallelFloworinCounterFlow ...8 2. 3 TheMeanDifferenceinTemperatureinReality ...12 2. 3. 1 FluidsinCrossFlow...14 2. 3. 2 HeatExchangers...15 2. 3. 3 Coils...19 2. 3. 4 TubeBankswithVariousPassagesoftheExternalFluid . 21 3 Veri?cation Computation ...25 3. 1 Introduction ...25 3. 2 FluidsinParallelFloworinCounterFlow ...25 3. 3 Factor?inRealCases...33 3. 3. 1 FluidswithCrossFlow ...

R4,298

Or split into 4x interest-free payments of 25% on orders over R50
Learn more

Discovery Miles42980
Mobicred@R403pm x 12* Mobicred Info
Free Delivery
Delivery AdviceShips in 10 - 15 working days


Toggle WishListAdd to wish list
Review this Item

Product Description

The recently published book by the author, "Engineering Heat Transfer", already dealt with exact computation of heat exchangers and tube banks. In design c- putationthisisaccomplishedviacorrectivefactors;thelattermakesitpossibleto compute the actual mean temperature difference by starting from the logarithmic onerelativeto?uidsinparallel?oworcounter?ow. As far as veri?cation computation is concerned, corrective factors were int- ducedtocomputeacertaincharacteristicfactorcorrectly,asisfundamentalforthis typeofcomputation. Basedontheabove,theauthordecidedtoinvestigatefurther,re?ne,andwiden thistopic:theoutcomeofthisworkhasresultedinthishandbook. Newtypesofexchangerswereexamined;thecalculationwasre?nedtoproduce practicallyexactvaluesforthefactors. Thescopeoftheinvestigationwasincreased by widening the range of the starting factors. Furthermore, a greater number of valuestobeincludedinthetableswasconsidered. Finally,afewcharacteristicsof certainvaluesofthecorrectivefactorswerehighlighted. The?rstsectionisanintroduction;itsummarizesthefundamentalcriteriaofheat transferandproceedstoillustratethebehaviorof?uidsinbothparallelandcounter ?ow. Italsoshowshowtocomputethemeanisobaricspeci?cheatforsome? uids; itillustratesthesigni?canceofdesigncomputationandveri?cationcomputation. In addition,itillustrateshowtoproceedwithheatexchangersandtubebankstocarry outbothdesignandveri?cationcomputationcorrectly. AppendixAthenincludes36tablesasareferencefordesigncomputation,The tablescontainthecorrectivefactorsrequiredtoobtaintheactualmeantemperature differencebystartingfromthemeanlogarithmictemperaturedifferencerelativeto ?uidsinparallel?oworcounter?ow. Finally, Appendix B includes 35 tables for veri?cation computation. As far as heatexchangers areconcerned, itshowsthevaluesoffactor ? whichisrequired forthistypeofcomputation. Thevaluesofthecorrectivefactorsforcoilsandtube banksarealsopresented. Milano,Italy DonatelloAnnaratone v Notation c=speci?cheat(J/kgK) d=diameter(m) E=ef?ciencyfactor h=enthalpy(kJ/kg) k=thermalconductivity(W/mK) M=mass?owrate(kg/s) m=massmoisturepercentage(%) q=heatpertimeunit(W) 2 S=surface(m ) ? t=temperature( C) 2 U=overallheattransfercoef?cient(W/m K) x=thickness(m) 2 ? =heattransfercoef?cient(W/m K) ? =characteristicfactor ? =characteristicfactor ? =ef?ciency ? =correctivefactor ? =correctivefactor ? =characteristicfactor ? ?t =temperaturedifference( C) vii viii Notation Superscripts =heating?uid =heated?uid Subscripts c=counter?ow e=exchanger i=inside l=logarithmic m=mean o=outside p=constantpressure(isobaric),parallel?ow w=wall 1=inlet(forheatingorheated?uid) 2=outlet(forheatingorheated?uid) Contents 1 Introduction to Computation ...1 1. 1 GeneralConsiderations ...1 1. 2 MeanIsobaricSpeci?cHeat ...3 1. 2. 1 WaterandSuperheatedSteam ...4 1. 2. 2 AirandOtherGases...4 2 Design Computation...7 2. 1 Introduction ...7 2. 2 FluidsinParallelFloworinCounterFlow ...8 2. 3 TheMeanDifferenceinTemperatureinReality ...12 2. 3. 1 FluidsinCrossFlow...14 2. 3. 2 HeatExchangers...15 2. 3. 3 Coils...19 2. 3. 4 TubeBankswithVariousPassagesoftheExternalFluid . 21 3 Veri?cation Computation ...25 3. 1 Introduction ...25 3. 2 FluidsinParallelFloworinCounterFlow ...25 3. 3 Factor?inRealCases...33 3. 3. 1 FluidswithCrossFlow ...

Customer Reviews

No reviews or ratings yet - be the first to create one!

Product Details

General

Imprint

Springer-Verlag

Country of origin

Germany

Release date

November 2014

Availability

Expected to ship within 10 - 15 working days

First published

2010

Authors

Dimensions

235 x 155 x 10mm (L x W x T)

Format

Paperback

Pages

176

Edition

2010 ed.

ISBN-13

978-3-642-42886-9

Barcode

9783642428869

Categories

LSN

3-642-42886-X



Trending On Loot