Energy Generation - Layout Plan for Hydro-Electric Power Project (Paperback)

, ,
Nara Canal is a perennial irrigation canal having six falls but two falls on the canal at RD 26 and RD 139 are found to be favourable for hydropower development. A number of layouts plan has been studied by collecting discharge data for the years 1995 to 2005 and flow duration curves were prepared to ascertain the availability of flows. For design discharge of the studied layouts, flow of 311 m3/s and 307 m3/s for Layout-A and Layout-B respectively which were available 30% time of the year were selected. Power potential and Energy output were evaluated for both layouts in comparying and finalization of layout scheme. The maximum power output for Layout-A and Layout-B was 5.5 MW and 8.11 MW respectively.The mean annual energy output expected for Layout-A and Layout-B was 35.5 GWh and 57.17 GWh respectively. Detailed results are presented in this technical book. The authors appreciate the efforts of Barthlemy Chaton and his team in facilitating and highly acknowledge publishing of it by VDM Publishing House Ltd., for technical knowledge sharing internationally.

R1,304

Or split into 4x interest-free payments of 25% on orders over R50
Learn more

Discovery Miles13040
Mobicred@R122pm x 12* Mobicred Info
Free Delivery
Delivery AdviceShips in 10 - 15 working days


Toggle WishListAdd to wish list
Review this Item

Product Description

Nara Canal is a perennial irrigation canal having six falls but two falls on the canal at RD 26 and RD 139 are found to be favourable for hydropower development. A number of layouts plan has been studied by collecting discharge data for the years 1995 to 2005 and flow duration curves were prepared to ascertain the availability of flows. For design discharge of the studied layouts, flow of 311 m3/s and 307 m3/s for Layout-A and Layout-B respectively which were available 30% time of the year were selected. Power potential and Energy output were evaluated for both layouts in comparying and finalization of layout scheme. The maximum power output for Layout-A and Layout-B was 5.5 MW and 8.11 MW respectively.The mean annual energy output expected for Layout-A and Layout-B was 35.5 GWh and 57.17 GWh respectively. Detailed results are presented in this technical book. The authors appreciate the efforts of Barthlemy Chaton and his team in facilitating and highly acknowledge publishing of it by VDM Publishing House Ltd., for technical knowledge sharing internationally.

Customer Reviews

No reviews or ratings yet - be the first to create one!

Product Details

General

Imprint

VDM Verlag

Country of origin

Germany

Release date

April 2010

Availability

Expected to ship within 10 - 15 working days

First published

April 2010

Authors

, ,

Dimensions

229 x 152 x 5mm (L x W x T)

Format

Paperback - Trade

Pages

76

ISBN-13

978-3-639-25051-0

Barcode

9783639250510

Categories

LSN

3-639-25051-6



Trending On Loot